Results 1 to 7 of 7

Thread: Light/UV Meter

  1. #1
    Member JasonO's Avatar
    Join Date
    Jun 2010
    Location
    St. Paul, Minnesota
    Posts
    172

    Light/UV Meter

    From the RCAAM Listserv, a recommendation for the Eltec 764 (http://www.conservationresources.com...ction20_17.htm):


    We have the pricey but lovely Eltec 764 UV and footcandle/lux reader. With shipping, around $1,350. It was recommended to us by the Midwest Art Conservation Center, and it is utterly simple to use. We bought ours with an NEH Preservation Assistance for Smaller Institutions grant.
    Karen

    - We are looking to purchase some collections related material. One of the things on my list for a long time is a

    - light meter that reads uv levels. Does anyone have a device they are particularly fond of? Thanks.
    -

    - Frank

  2. #2
    PACCIN Advisory Committee Member T. Ashley McGrew's Avatar
    Join Date
    Feb 2010
    Location
    San Francisco, CA
    Posts
    556
    Another worthy contribution from Bruce MacLeish on the RCAAM List 7/11`/2011
    ************************************************** **********

    From:Bruce MacLeish <bruce@NEWPORTRESTORATION.ORG>

    View ContactTo:RCAAM@SI-LISTSERV.SI.EDU
    George, I have followed this trail, in search of reasonably-priced meters. I’m afraid the Littlemore Scientific (Elsec) models were out of my league, but I have been using a couple of meters that might be of interest to you. I am not sure where my trusty (old) visible light meter came from, but <professionalequipment.com> carries quite an assortment, from under $100. I would probably aim for one of the Extech meters, at about $160. By the way, I can check the performance with my photographic light meter, a Gossen Luna Pro Digital and a conversion scale.

    I have a separate UV meter, Mannix UV-340 (now General Tools UV513AB) which does a good job. If I had the money, I would upgrade to something a bit more elegant, but it’s a big leap to the next level, which seems to be about $700. There are a number of services which still calibrate the meter I have, so I will keep using it. And you are correct, just because you don’t have natural light does not mean that UV energy is not sneaking into your exhibit or storage areas somehow. If you don’t have the means of checking your light, how would you be sure? You might like the variety of meters on <valuetesters.com>

    Good luck with your purchases.

    Bruce

    A. Bruce MacLeish
    Director of Collections
    Newport Restoration Foundation
    51 Touro Street
    Newport, RI 02840
    T. Ashley McGrew
    PACCIN Advisory Committee member

  3. #3
    Member JasonO's Avatar
    Join Date
    Jun 2010
    Location
    St. Paul, Minnesota
    Posts
    172
    More ideas from RCAAM:

    http://www.apsnyc.com/index.php?page=light-measurement

    We have an Elsec for our institution and we felt it was a good investment for the long term.

    http://www.sperdirect.com/cgi-bin/ca...y=chartuvlight

    We purchased the Elsec 764 directly from the manufacturer in the UK.

    http://www.elsec.com/acatalog/764.html

    Given the exchange rate, we were able to save a considerable amount of money, and shipping charges were very reasonable.

  4. #4

    Light meters

    Quote Originally Posted by T. Ashley McGrew View Post
    Another worthy contribution from Bruce MacLeish on the RCAAM List 7/11`/2011
    ************************************************** **********

    From:Bruce MacLeish <bruce@NEWPORTRESTORATION.ORG>

    View ContactTo:RCAAM@SI-LISTSERV.SI.EDU
    George, I have followed this trail, in search of reasonably-priced meters. I’m afraid the Littlemore Scientific (Elsec) models were out of my league, but I have been using a couple of meters that might be of interest to you. I am not sure where my trusty (old) visible light meter came from, but <professionalequipment.com> carries quite an assortment, from under $100. I would probably aim for one of the Extech meters, at about $160. By the way, I can check the performance with my photographic light meter, a Gossen Luna Pro Digital and a conversion scale.

    I have a separate UV meter, Mannix UV-340 (now General Tools UV513AB) which does a good job. If I had the money, I would upgrade to something a bit more elegant, but it’s a big leap to the next level, which seems to be about $700. There are a number of services which still calibrate the meter I have, so I will keep using it. And you are correct, just because you don’t have natural light does not mean that UV energy is not sneaking into your exhibit or storage areas somehow. If you don’t have the means of checking your light, how would you be sure? You might like the variety of meters on <valuetesters.com>

    Good luck with your purchases.

    Bruce

    A. Bruce MacLeish
    Director of Collections
    Newport Restoration Foundation
    51 Touro Street
    Newport, RI 02840

    After doing much on-line reseach on this, I found that the more expesive meters are no more accurate than the less expensive models.

    John Dreckmann
    Lighting Preparator
    Milwaukee Art Museum

  5. #5
    After doing much on-line reseach on this, I found that the more expensive meters are no more accurate than the less expensive models.

    John Dreckmann
    Lighting Preparator
    Milwaukee Art Museum

  6. #6
    Member JasonO's Avatar
    Join Date
    Jun 2010
    Location
    St. Paul, Minnesota
    Posts
    172

    Another meter

    This light meter was just recommended on RCAAM. It doesn't have UV, but looks like it is pretty easy to use for measuring basic light levels.

    (http://www.sekonic.com/Products/i-346/Overview.aspx)

    Jason

  7. #7
    Member JasonO's Avatar
    Join Date
    Jun 2010
    Location
    St. Paul, Minnesota
    Posts
    172
    Here is a new recommendation from the PACCIN Listserv (posted with permission).

    The question was "Today I'm looking for recommendations for a digital light meter that can do readings in lux and foot candles. My photography background has me leaning towards a Sekonic but I wonder if there is another museum/gallery favorite out there."

    Here is Scott's answer:


    Whatever you get, make sure it’s an illuminance meter (not just a light meter that may read in f-stops rather than Lux or foot-candles). I am not familiar with the Sekonic illuminance meters, they are relatively inexpensive -- it would be great if they are reliable. Here is what I know:

    The Elsec meter is probably the most expensive (and best) illuminance meter for museum applications. It’s my favorite best because it has options (at additional cost) to add UV, IR, Temp and Humidity measurements.

    http://www.elsec.com/acatalog/EMon.html

    I typically use meters by Cooke (Cal light 400-f) for illuminance readings on museum objects. I like the Cooke meter because it can switch from Footcandles to Lux, it automatically shuts off, it’s half the price of the Elsec, and it’s instant on (it doesn’t require recalibration with a lens cap). Minolta also makes fantastic meters , but I think they only measures in either footcandles or Lux.

    http://www.cookecorp.com/industrial-...al-light-400f/

    Lastly, I’ve purchased an inexpensive meter from Extech. That meter regularly fell apart (required re-soldering of connections) and after 5 years the electronics gave out. Whatever meter you purchase make sure that a NIST certificate is available. I have no idea if it’s worth the price to actually purchase the certificate, but not offering the option of a certificate is deal breaker for me.

    Scott


    Scott Rosenfeld, LC, IESNA
    Smithsonian American Art Museum

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •